Lazaros Vlachopoulos
Correction of complex three-dimensional deformities at the proximal femur using indirect reduction with angle blade plate and patient-specific instruments: a technical note
Jud L, Vlachopoulos L, Grob K. Correction of complex three-dimensional deformities at the proximal femur using indirect reduction with angle blade plate and patient-specific instruments: a technical note. J Orthop Surg Res 2021; 16:427.
03.07.2021Correction of complex three-dimensional deformities at the proximal femur using indirect reduction with angle blade plate and patient-specific instruments: a technical note
03.07.2021J Orthop Surg Res 2021; 16:427
Jud Lukas, Vlachopoulos Lazaros, Grob Karl
Influence of medial open wedge high tibial osteotomy on tibial tuberosity-trochlear groove distance
Hodel S, Zindel C, Jud L, Vlachopoulos L, Fürnstahl P, Fucentese S. Influence of medial open wedge high tibial osteotomy on tibial tuberosity-trochlear groove distance. Knee Surg Sports Traumatol Arthrosc 2021
23.04.2021Influence of medial open wedge high tibial osteotomy on tibial tuberosity-trochlear groove distance
23.04.2021Knee Surg Sports Traumatol Arthrosc 2021
Hodel Sandro, Zindel Christoph, Jud Lukas, Vlachopoulos Lazaros, Fürnstahl Philipp, Fucentese Sandro F
A real 3D measurement technique for the tibial slope: differentiation between different articular surfaces and comparison to radiographic slope measurement
Hoch A, Jud L, Roth T, Vlachopoulos L, Fürnstahl P, Fucentese S. A real 3D measurement technique for the tibial slope: differentiation between different articular surfaces and comparison to radiographic slope measurement. BMC Musculoskelet Disord 2020; 21:635.
26.09.2020A real 3D measurement technique for the tibial slope: differentiation between different articular surfaces and comparison to radiographic slope measurement
26.09.2020BMC Musculoskelet Disord 2020; 21:635
Hoch Armando, Jud Lukas, Roth Tabitha, Vlachopoulos Lazaros, Fürnstahl Philipp, Fucentese Sandro F
Mal-angulation of femoral rotational osteotomies causes more postoperative sagittal mechanical leg axis deviation in supracondylar than in subtrochanteric procedures
Jud L, Andronic O, Vlachopoulos L, Fucentese S, Zingg P. Mal-angulation of femoral rotational osteotomies causes more postoperative sagittal mechanical leg axis deviation in supracondylar than in subtrochanteric procedures. J Exp Orthop 2020; 7:46.
01.07.2020Mal-angulation of femoral rotational osteotomies causes more postoperative sagittal mechanical leg axis deviation in supracondylar than in subtrochanteric procedures
01.07.2020J Exp Orthop 2020; 7:46
Jud Lukas, Andronic Octavian, Vlachopoulos Lazaros, Fucentese Sandro F, Zingg Patrick O
The impact of limb loading and the measurement modality (2D versus 3D) on the measurement of the limb loading dependent lower extremity parameters
Jud L, Roth T, Fürnstahl P, Vlachopoulos L, Sutter R, Fucentese S. The impact of limb loading and the measurement modality (2D versus 3D) on the measurement of the limb loading dependent lower extremity parameters. BMC Musculoskelet Disord 2020; 21:418.
30.06.2020The impact of limb loading and the measurement modality (2D versus 3D) on the measurement of the limb loading dependent lower extremity parameters
30.06.2020BMC Musculoskelet Disord 2020; 21:418
Jud Lukas, Roth Tabitha, Fürnstahl Philipp, Vlachopoulos Lazaros, Sutter Reto, Fucentese Sandro F
Combined Correction of Tibial Torsion and Tibial Tuberosity-Trochlear Groove Distance by Supratuberositary Torsional Osteotomy of the Tibia
Jud L, Singh S, Tondelli T, Fürnstahl P, Fucentese S, Vlachopoulos L. Combined Correction of Tibial Torsion and Tibial Tuberosity-Trochlear Groove Distance by Supratuberositary Torsional Osteotomy of the Tibia. Am J Sports Med 2020; 48:2260-2267.
18.06.2020Combined Correction of Tibial Torsion and Tibial Tuberosity-Trochlear Groove Distance by Supratuberositary Torsional Osteotomy of the Tibia
18.06.2020Am J Sports Med 2020; 48:2260-2267
Jud Lukas, Singh Sarvpreet, Tondelli Timo, Fürnstahl Philipp, Fucentese Sandro F, Vlachopoulos Lazaros
Meniscus sizing using three-dimensional models of the ipsilateral tibia plateau based on CT scans - an experimental study of a new sizing approach
Beeler S, Vlachopoulos L, Jud L, Sutter R, Götschi T, Fürnstahl P, Fucentese S. Meniscus sizing using three-dimensional models of the ipsilateral tibia plateau based on CT scans - an experimental study of a new sizing approach. J Exp Orthop 2020; 7:36.
27.05.2020Meniscus sizing using three-dimensional models of the ipsilateral tibia plateau based on CT scans - an experimental study of a new sizing approach
27.05.2020J Exp Orthop 2020; 7:36
Beeler Silvan, Vlachopoulos Lazaros, Jud Lukas, Sutter Reto, Götschi Tobias, Fürnstahl Philipp, Fucentese Sandro F
Accuracy of 3D-planned patient specific instrumentation in high tibial open wedge valgisation osteotomy
Fucentese S, Meier P, Jud L, Köchli G, Aichmair A, Vlachopoulos L, Fürnstahl P. Accuracy of 3D-planned patient specific instrumentation in high tibial open wedge valgisation osteotomy. J Exp Orthop 2020; 7:7.
27.02.2020Accuracy of 3D-planned patient specific instrumentation in high tibial open wedge valgisation osteotomy
27.02.2020J Exp Orthop 2020; 7:7
Fucentese Sandro F, Meier Patrick, Jud Lukas, Köchli Gian-Luca, Aichmair Alexander, Vlachopoulos Lazaros, Fürnstahl Philipp
Three-dimensional meniscus allograft sizing-a study of 280 healthy menisci
Beeler S, Jud L, von Atzigen M, Sutter R, Fürnstahl P, Fucentese S, Vlachopoulos L. Three-dimensional meniscus allograft sizing-a study of 280 healthy menisci. J Orthop Surg Res 2020; 15:74.
24.02.2020Three-dimensional meniscus allograft sizing-a study of 280 healthy menisci
24.02.2020J Orthop Surg Res 2020; 15:74
Beeler Silvan, Jud Lukas, von Atzigen Marco, Sutter Reto, Fürnstahl Philipp, Fucentese Sandro F, Vlachopoulos Lazaros
Accuracy of three dimensional-planned patient-specific instrumentation in femoral and tibial rotational osteotomy for patellofemoral instability
Jud L, Vlachopoulos L, Beeler S, Tondelli T, Fürnstahl P, Fucentese S. Accuracy of three dimensional-planned patient-specific instrumentation in femoral and tibial rotational osteotomy for patellofemoral instability. Int Orthop 2020; 44:1711-1717.
13.02.2020Accuracy of three dimensional-planned patient-specific instrumentation in femoral and tibial rotational osteotomy for patellofemoral instability
13.02.2020Int Orthop 2020; 44:1711-1717
Jud Lukas, Vlachopoulos Lazaros, Beeler Silvan, Tondelli Timo, Fürnstahl Philipp, Fucentese Sandro F
The impact of mal-angulated femoral rotational osteotomies on mechanical leg axis: a computer simulation model
Jud L, Vlachopoulos L, Häller T, Fucentese S, Rahm S, Zingg P. The impact of mal-angulated femoral rotational osteotomies on mechanical leg axis: a computer simulation model. BMC Musculoskelet Disord 2020; 21:50.
23.01.2020The impact of mal-angulated femoral rotational osteotomies on mechanical leg axis: a computer simulation model
23.01.2020BMC Musculoskelet Disord 2020; 21:50
Jud Lukas, Vlachopoulos Lazaros, Häller Thomas V, Fucentese Sandro F, Rahm Stefan, Zingg Patrick O
Rotation or flexion alters mechanical leg axis measurements comparably in patients with different coronal alignment
Jud L, Trache T, Tondelli T, Fürnstahl P, Fucentese S, Vlachopoulos L. Rotation or flexion alters mechanical leg axis measurements comparably in patients with different coronal alignment. Knee Surg Sports Traumatol Arthrosc 2019; 28:3128-3134.
08.11.2019Rotation or flexion alters mechanical leg axis measurements comparably in patients with different coronal alignment
08.11.2019Knee Surg Sports Traumatol Arthrosc 2019; 28:3128-3134
Jud Lukas, Trache Tudor, Tondelli Timo, Fürnstahl Philipp, Fucentese Sandro F, Vlachopoulos Lazaros
Contralateral MRI scan can be used reliably for three-dimensional meniscus sizing - Retrospective analysis of 160 healthy menisci
Beeler S, Vlachopoulos L, Jud L, Sutter R, Fürnstahl P, Fucentese S. Contralateral MRI scan can be used reliably for three-dimensional meniscus sizing - Retrospective analysis of 160 healthy menisci. Knee 2019; 26:954-961.
18.08.2019Contralateral MRI scan can be used reliably for three-dimensional meniscus sizing - Retrospective analysis of 160 healthy menisci
18.08.2019Knee 2019; 26:954-961
Beeler Silvan, Vlachopoulos Lazaros, Jud Lukas, Sutter Reto, Fürnstahl Philipp, Fucentese Sandro F
Joint-preserving tumour resection around the knee with allograft reconstruction using three-dimensional preoperative planning and patient-specific instruments
Jud L, Müller D, Fürnstahl P, Fucentese S, Vlachopoulos L. Joint-preserving tumour resection around the knee with allograft reconstruction using three-dimensional preoperative planning and patient-specific instruments. Knee 2019; 26:787-793.
16.03.2019Joint-preserving tumour resection around the knee with allograft reconstruction using three-dimensional preoperative planning and patient-specific instruments
16.03.2019Knee 2019; 26:787-793
Jud Lukas, Müller Daniel A, Fürnstahl Philipp, Fucentese Sandro F, Vlachopoulos Lazaros
Malpositioning of patient-specific instruments within the possible degrees of freedom in high-tibial osteotomy has no considerable influence on mechanical leg axis correction
Jud L, Fürnstahl P, Vlachopoulos L, Götschi T, Leoty L, Fucentese S. Malpositioning of patient-specific instruments within the possible degrees of freedom in high-tibial osteotomy has no considerable influence on mechanical leg axis correction. Knee Surg Sports Traumatol Arthrosc 2019; 28:1356-1364.
26.02.2019Malpositioning of patient-specific instruments within the possible degrees of freedom in high-tibial osteotomy has no considerable influence on mechanical leg axis correction
26.02.2019Knee Surg Sports Traumatol Arthrosc 2019; 28:1356-1364
Jud Lukas, Fürnstahl Philipp, Vlachopoulos Lazaros, Götschi Tobias, Leoty Laura Catherine, Fucentese Sandro F