Kurzbeschreibung/Zielsetzung

To evaluate feasibility and functional effects of photodynamic endometrial ablation (PEA) in patients.


Study Design/Patients and Methods


A total of 15 PEAs has been performed in 11 patients using topically applied 5-aminolevulinic acid (ALA) solutions and a balloon-light diffuser (160 J/cm2, 635 nm). Uterine bleeding intensity has been determined on a daily basis 3 months prior to and up to 6 months after endometrial ablation using an analogous scale scoring from 1 (spotting) to 6 U (severe bleeding). Statistical analysis by unpaired Student's t-test.


Results


The mean number of bleeding units per cycle (n = 44) was 35.7 prior to PEA. The decrease in bleeding units was significant for the months 1–3 (24.4 U per cycle; P = 0.03), but not for the months 4–6 (25.9 U; P = 0.11) following PEA.