Publikation
The Reuse of Immunoadsorption Columns in ABO-Incompatible Kidney Transplantation Is Efficient: The Swiss Experience
Wissenschaftlicher Artikel/Review - 21.10.2014
Schiesser Marc, Steinemann Daniel C, Hadaya Karine, Huyen-Do Uyen, Eisenberger Ute, Binet Françoise-Isabelle, Fehr Thomas, Dickenmann Michael
Bereiche
PubMed
DOI
Zitation
Art
Zeitschrift
Veröffentlichungsdatum
eISSN (Online)
Kurzbeschreibung/Zielsetzung
BACKGROUND
We developed a multicentric Swiss protocol for ABO-incompatible kidney transplantation including immunoadsorption column reuse. The aim of this study was to assess efficacy and safety of immunoadsorption column reuse in ABO-incompatible kidney transplantation.
METHODS
We performed a multicentric prospective trial including all ABO-incompatible kidney transplantations in Switzerland from 2005 to 2011. Patients received rituximab and standardized immunosuppression with tacrolimus, mycophenolate mofetil, and steroids. Antigen-specific perioperative immunoadsorption was performed. Immunoadsorption columns were reused after restoration. Graft survival, patient survival, kidney function, rejections, number of columns, adverse events after column reuse, and anti-A/anti-B antibody titers were assessed.
RESULTS
Seventy-one ABO-incompatible patients underwent antigen-specific immunoadsorption and could be transplanted across the blood group barrier. Kaplan-Meier estimates for both, patient-censored and death-censored graft survivals were both 97.2% at 5 years. Allograft function was excellent with a mean estimated glomerular filtration rate of 54 mL per min after 1 year. The median number of pretransplant immunoadsorptions was 5. All centers performed column reuse. A total of 394 immunoadsorption procedures were performed with reused filters. Patient survival, graft survival, and adverse events did not differ when filters were reused. Column reuse resulted in cost savings of 21,458 USD per patient.
CONCLUSION
We have introduced a national protocol for ABO-incompatible kidney transplantation including immunoadsorption column reuse. Column reuse was efficient and safe.