Karl Stoffel
The position and number of screws influence screw perforation of the humeral head in modern locking plates: a cadaver study
Erhardt J, Stoffel K, Kampshoff J, Badur N, Yates P, Kuster M. The position and number of screws influence screw perforation of the humeral head in modern locking plates: a cadaver study. J Orthop Trauma 2012; 26:e188-92.
01.10.2012The position and number of screws influence screw perforation of the humeral head in modern locking plates: a cadaver study
01.10.2012J Orthop Trauma 2012; 26:e188-92
Erhardt Johannes, Stoffel Karl, Kampshoff Jorg, Badur Nicole, Yates Piers, Kuster Markus
Patellofemoral contact pressure following high tibial osteotomy: a cadaveric study
Stoffel K, Willers C, Korshid O, Kuster M. Patellofemoral contact pressure following high tibial osteotomy: a cadaveric study. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA 2007; 15:1094-100.
01.09.2007Patellofemoral contact pressure following high tibial osteotomy: a cadaveric study
01.09.2007Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA 2007; 15:1094-100
Stoffel Karl, Willers Craig, Korshid Omar, Kuster Markus
Biomechanical considerations in plate osteosynthesis: the effect of plate-to-bone compression with and without angular screw stability
Stoffel K, Lorenz K, Kuster M. Biomechanical considerations in plate osteosynthesis: the effect of plate-to-bone compression with and without angular screw stability. Journal of orthopaedic trauma 2007; 21:362-8.
01.07.2007Biomechanical considerations in plate osteosynthesis: the effect of plate-to-bone compression with and without angular screw stability
01.07.2007Journal of orthopaedic trauma 2007; 21:362-8
Stoffel Karl, Lorenz Kai-Uwe, Kuster Markus
Changes in biochemical markers after lower limb fractures
Stoffel K, Engler H, Kuster M, Riesen W. Changes in biochemical markers after lower limb fractures. Clinical chemistry 2007; 53:131-4.
01.01.2007Changes in biochemical markers after lower limb fractures
01.01.2007Clinical chemistry 2007; 53:131-4
Stoffel Karl, Engler Hanna, Kuster Markus, Riesen Walter
A comparison of conventional versus locking plates in intraarticular calcaneus fractures: a biomechanical study in human cadavers
Stoffel K, Booth G, Rohrl S, Kuster M. A comparison of conventional versus locking plates in intraarticular calcaneus fractures: a biomechanical study in human cadavers. Clinical biomechanics (Bristol, Avon) 2007; 22:100-5.
01.01.2007A comparison of conventional versus locking plates in intraarticular calcaneus fractures: a biomechanical study in human cadavers
01.01.2007Clinical biomechanics (Bristol, Avon) 2007; 22:100-5
Stoffel Karl, Booth Grant, Rohrl Stephan M, Kuster Markus
Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers
Blythe M, Stoffel K, Jarrett P, Kuster M. Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers. The Journal of hand surgery 2006; 31:1587-93.
01.12.2006Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers
01.12.2006The Journal of hand surgery 2006; 31:1587-93
Blythe Murray, Stoffel Karl, Jarrett Paul, Kuster Markus
Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex Osteotomy Plate (Puddu Plate) and the TomoFix Plate
Stoffel K, Stachowiak G, Kuster M. Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex Osteotomy Plate (Puddu Plate) and the TomoFix Plate. Clinical biomechanics (Bristol, Avon) 2004; 19:944-50.
01.11.2004Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex Osteotomy Plate (Puddu Plate) and the TomoFix Plate
01.11.2004Clinical biomechanics (Bristol, Avon) 2004; 19:944-50
Stoffel Karl, Stachowiak Gwidon, Kuster Markus
Oblique screws at the plate ends increase the fixation strength in synthetic bone test medium
Stoffel K, Stachowiak G, Forster T, Gächter A, Kuster M. Oblique screws at the plate ends increase the fixation strength in synthetic bone test medium. Journal of orthopaedic trauma 2004; 18:611-6.
01.10.2004Oblique screws at the plate ends increase the fixation strength in synthetic bone test medium
01.10.2004Journal of orthopaedic trauma 2004; 18:611-6
Stoffel Karl, Stachowiak Gwidon, Forster Thomas, Gächter André, Kuster Markus
Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?
Stoffel K, Dieter U, Stachowiak G, Gächter A, Kuster M. Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?. Injury 2003; 34 Suppl 2:B11-9.
01.11.2003Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?
01.11.2003Injury 2003; 34 Suppl 2:B11-9
Stoffel Karl, Dieter Ulrich, Stachowiak Gwidon, Gächter André, Kuster Markus