Publikation

Collagen-bound fibrin sealant (TachoSil®) for dural closure in cranial surgery: single-centre comparative cohort study and systematic review of the literature.

Wissenschaftlicher Artikel/Review - 02.11.2022

Bereiche
PubMed
DOI
Kontakt

Zitation
Carretta A, Epskamp M, Ledermann L, Staartjes V, Neidert M, Regli L, Stienen M. Collagen-bound fibrin sealant (TachoSil®) for dural closure in cranial surgery: single-centre comparative cohort study and systematic review of the literature. Neurosurg Rev 2022; 45:3779-3788.
Art
Wissenschaftlicher Artikel/Review (Englisch)
Zeitschrift
Neurosurg Rev 2022; 45
Veröffentlichungsdatum
02.11.2022
eISSN (Online)
1437-2320
Seiten
3779-3788
Kurzbeschreibung/Zielsetzung

Cerebrospinal fluid (CSF) leakage is a well-known complication of craniotomies and there are several dural closure techniques. One commonly used commercial product as adjunct for dural closure is the collagen-bound fibrin sealant TachoSil®. We analysed whether the addition of TachoSil has beneficial effects on postoperative complications and outcomes. Our prospective, institutional database was retrospectively queried, and 662 patients undergoing craniotomy were included. Three hundred fifty-two were treated with dural suture alone, and in 310, TachoSil was added after primary suture. Our primary endpoint was the rate of postoperative complications associated with CSF leakage. Secondary endpoints included functional, disability and neurological outcome. Systematic review according to PRISMA guidelines was performed to identify studies comparing primary dural closure with and without additional sealants. Postoperative complications associated with CSF leakage occurred in 24 (7.74%) and 28 (7.95%) procedures with or without TachoSil, respectively (p = 0.960). Multivariate analysis confirmed no significant differences in complication rate between the two groups (aOR 0.97, 95% CI 0.53-1.80, p = 0.930). There were no significant disparities in postoperative functional, disability or neurological scores. The systematic review identified 661 and included 8 studies in the qualitative synthesis. None showed a significant superiority of additional sealants over standard technique regarding complications, rates of revision surgery or outcome. According to our findings, we summarize that routinary use of TachoSil and similar products as adjuncts to primary dural sutures after intracranial surgical procedures is safe but without clear advantage in complication avoidance or outcome. Future studies should investigate whether their use is beneficial in high-risk settings.