Publikation
Impact of propofol sedation on the diagnostic accuracy of hepatic venous pressure gradient measurements in patients with cirrhosis
Wissenschaftlicher Artikel/Review - 26.10.2021
Ebrahimi Fahim, Semela David, Heim Markus
Bereiche
PubMed
DOI
Zitation
Art
Zeitschrift
Veröffentlichungsdatum
eISSN (Online)
Kurzbeschreibung/Zielsetzung
BACKGROUND
Measurement of the hepatic venous pressure gradient (HVPG) is the gold standard to evaluate the presence and severity of portal hypertension. The procedure is generally safe and well tolerated, but nevertheless, some patients demand for sedation. However, it is unknown whether propofol sedation would impair the accuracy of portal pressure measurements.
METHODS
This is a prospective observational cohort study including cirrhotic patients with suspected portal hypertension undergoing invasive measurement of HVPG. Measurements of HVPG were performed in awake condition as well as under sedation with propofol infusion.
RESULTS
In total, 37 patients were included. Mean HVPG in awake condition was 15.9 mmHg (IQR 13-19) and during sedation 14.1 mmHg (IQR 12-17). While measures of free hepatic vein pressure (FHVP) were not altered after propofol sedation (p = 0.34), wedged hepatic vein pressure values (WHVP) decreased in an average by 2.05 mmHg (95% CI - 2.46 to - 1.16; p < 0.001) which was proportional to the magnitude of HVPG. In 31 out of 37 patients (83.8%), portal hypertension with HVPG ≥ 12 mmHg was found. Under sedation with propofol, two patients (5.4%) with borderline values would have been incorrectly classified as < 12 mmHg. After adjustment for the average difference of - 10%, all patients were correctly classified. Intraclass correlation coefficient between HVPG measurement in awake condition and under propofol sedation was 0.927 (95% CI 0.594-0.975).
CONCLUSIONS
Propofol sedation during HVPG measurements is generally safe, however it may lead to relevant alterations of HVPG readings.