Publication

CT-Osteoabsorptiometry (CT-OAM) - a new investigation technique in the field of mummy research

Journal Paper/Review - Apr 4, 2017

Units
PubMed
Doi

Citation
Hirsch A, Hotz G, Rosendahl W, Zumstein V, Rühli F, Müller-Gerbl M. CT-Osteoabsorptiometry (CT-OAM) - a new investigation technique in the field of mummy research. Anthropol Anz 2017; 74:1-7.
Type
Journal Paper/Review (English)
Journal
Anthropol Anz 2017; 74
Publication Date
Apr 4, 2017
Issn Print
0003-5548
Pages
1-7
Brief description/objective

ABSTRACT
The scientific study of mummies provides an insight into the life of past populations. Using CT-Osteoabsorptiometry (CT-OAM), a noninvasive technique based on conventional CT-data sets, it is possible to visualize the mineral density distribution in the subchondral bone plate, representing the long-term loading conditions of the articulation surface. The objective of the current study was to investigate the applicability of CT-OAM on mummies for the load analysis of joints as a new investigation technique in the field of mummy research. In order to clarify if apparent malpositions of the spinal column have existed during lifetime or occurred post-mortem, we evaluated the long-term loading patterns within the thoracic and lumbar endplates of 8 mummies. The implementation of CT-OAM on mummies for load analysis of joints was feasible. The mineral density distribution within the endplates was not homogenous but followed distinct distribution patterns. In all of the endplates investigated the marginal zones were higher and the central areas lower mineralized, whereby the areas of greatest density were found in the peripheral marginal zones. The vertebra columns without malposition showed within the thoracic endplates an almost even circular allocation of the density maxima, whereas within the lumbar endplates an increased localization of the density maxima dorsomedial, dorsolateral and ventral was observed. The thoracic endplates of the spines with kyphosis did not show an even circular allocation anymore but a concentration of the density maxima in the ventral area and the endplates of the spines with scoliosis exhibited a predominant localization of the density maxima on the concave side. The examined endplates showed characteristic reproducible density patterns consistent with the long-term loading conditions. With help of CT-OAM pathological load distributions can be visualized before macroscopical changes appear and the information obtained can be useful to solve paleopathological and paleoarchaeological questions.