Publication

Monitoring c-reactive protein after laparoscopic colorectal surgery excludes infectious complications and allows for safe and early discharge

Journal Paper/Review - May 23, 2014

Units
PubMed
Doi

Citation
Adamina M, Warschkow R, Näf F, Hummel B, Rduch T, Lange J, Steffen T. Monitoring c-reactive protein after laparoscopic colorectal surgery excludes infectious complications and allows for safe and early discharge. Surg Endosc 2014; 28:2939-48.
Type
Journal Paper/Review (English)
Journal
Surg Endosc 2014; 28
Publication Date
May 23, 2014
Issn Electronic
1432-2218
Pages
2939-48
Brief description/objective

BACKGROUND
Early detection of infectious complications is urgently needed in the era of DRG-based compensation. This work assessed the diagnostic accuracy of c-reactive protein (CRP) level in the detection of infectious complications after laparoscopic colorectal resection.

METHODS
Laparoscopic colorectal resections were identified from a prospective database. Complications were graded according to the Dindo-Clavien classification. Surgical site infections were defined according to the Centers of Disease Control. CRP level was routinely measured until postoperative day (POD) 7. Uni- and multivariate analysis were performed. Diagnostic accuracy was evaluated using receiver operating curves.

RESULTS
355 patients were operated for diverticulosis (88.7%), neoplasia (6.8%), and other causes (4.5%). Mean age and body mass index were 59.8 ± 13.7 years and 26.5 ± 15 kg/m(2). Left, right, and total laparoscopic colectomies were performed in 316, 33, and 6 patients. Complications occurred in 85 patients and 16 patients (4.5%) were reoperated. Fifty-one patients (14.4%) suffered from infectious complications at a median of 6 POD, while 9 anastomoses leaked (2.7%). In multivariate analysis, presence of an abscess at surgery was predictive of an infectious complication (OR 2.5, 95% CI 1.1-5.3), as were a body mass index >30 kg/m(2) and operative time >160 min in a bootstrap analysis. Overall, CRP peaked on POD 2 and declined thereafter. Most infectious complications were apparent starting on POD 6. A CRP <56 mg/l on POD 4 had a negative predictive value of 100% (95% CI 94.9-100%) to rule out infectious complications. Above 56 mg/l, sensitivity was 100% (95% CI 0.8-1) and specificity 49% (95% CI 0.4-0.6) for the development of infectious complications in the absence of clinical signs. This translated into a remarkable diagnostic accuracy of 78% (95% CI 0.7-0.9).

CONCLUSION
Monitoring CRP level in laparoscopic colorectal surgery demonstrated a high diagnostic accuracy for infectious complications, thus allowing for safe and early discharge.