Publication

Second generation locked plating of proximal humerus fractures--a prospective multicentre observational study

Journal Paper/Review - Apr 25, 2010

Units
PubMed
Doi
Contact

Citation
Röderer G, Erhardt J, Kuster M, Vegt P, Bahrs C, Kinzl L, Gebhard F. Second generation locked plating of proximal humerus fractures--a prospective multicentre observational study. Int Orthop 2010; 35:425-32.
Type
Journal Paper/Review (English)
Journal
Int Orthop 2010; 35
Publication Date
Apr 25, 2010
Issn Electronic
1432-5195
Pages
425-32
Brief description/objective

Surgical treatment of most displaced proximal humerus fractures is challenging due to osteoporosis. Locking plates are intended to provide superior mechanical stability. In a prospective multicentre study 131 patients were treated with second generation locked plating (NCB-PH, Zimmer, Inc.). The open procedure (n = 78) was performed using a deltopectoral approach; the minimally invasive technique (n = 53) involved percutaneous reduction and an anterolateral deltoid split approach. Clinical and radiological follow-up was obtained. Improvement in function (ROM) was statistically significant. Fracture type (AO) had the most significant impact on the incidence of complications. The most frequent complications detected were intra-articular screw perforation (15%) and secondary displacement (8%). Complication rate and functional outcome of the NCB-PH are comparable to reports in the literature. Not all problems are likely to be solved by this new generation of implants, i.e. secondary dislocation still occurred in 8% of our patients.