Publication

Long term angiographic and clinical follow up in patients with stent implantation for symptomatic myocardial bridging

Journal Paper/Review - Oct 1, 2000

Units
PubMed

Citation
Haager P, Schwarz E, vom Dahl J, Klues H, Reffelmann T, Hanrath P. Long term angiographic and clinical follow up in patients with stent implantation for symptomatic myocardial bridging. Heart (British Cardiac Society) 2000; 84:403-8.
Type
Journal Paper/Review (English)
Journal
Heart (British Cardiac Society) 2000; 84
Publication Date
Oct 1, 2000
Issn Electronic
1468-201X
Pages
403-8
Brief description/objective

OBJECTIVE: To assess long term results of coronary stent implantation in patients with symptomatic myocardial bridging. METHODS: Intracoronary stent implantation was performed within the intramural course of the left anterior descending coronary artery in 11 patients with objective signs of myocardial ischaemia and absence of other cardiac disorders. All had myocardial bridging of the central portion of the left anterior descending coronary artery. Quantitative coronary angiography was performed before and after stent deployment, and again at seven weeks and six months. Clinical evaluation was done at two years. RESULTS: After stent deployment, quantitative coronary angiography showed absence of systolic compression along the left anterior descending coronary artery; the minimum luminal diameter (mean (SD)) increased from 0.6 (0.3) mm before stent implantation to 1.9 (0.3) mm after implantation (p < 0. 05). Intravascular ultrasound showed an increase in cross sectional area from 3.3 (1.3) mm(2) at baseline to 6.8 (0.9) mm(2) (p < 0.005) after stent deployment. Coronary flow reserve was normalised from 2. 6 (0.5) at baseline to 4.0 (0.5) (p < 0.005) after stent implantation. At seven weeks, quantitative coronary angiography showed mild to moderate or severe in-stent stenosis in five of the 11 patients; four of these underwent repeat target vessel revascularisation (percutaneous transluminal coronary angioplasty in two; coronary artery bypass grafting in two). At six months, all patients (n = 9) showed good angiographic results, including those who had target vessel revascularisation. On clinical evaluation at two years, all patients (including those with target vessel revascularisation) remained free of angina and cardiac events. CONCLUSIONS: Intracoronary stent implantation prevents external compression of bridged coronary artery segments, with increase in luminal diameter and alleviation of symptoms. The incidence of in-stent stenosis requiring target vessel revascularisation (36%) is comparable with that of lesions of 25 mm length in coronary artery disease. The symptom free and event free two year follow up data suggest that stent implantation is a useful way of treating symptomatic patients with myocardial bridges.