Publication
Impact of a Surgical Sealing Patch on Lymphatic Drainage After Axillary Dissection for Breast Cancer: The SAKK 23/13 Multicenter Randomized Phase III Trial
Journal Paper/Review - Jun 8, 2018
Weber Walter Paul, Sarlos Dimitri, Leo Cornelia, Canonica Claudia, Gabriel Natalie, Zeindler Jasmin, Cassoly Estelle, Andrieu Christiane, Soysal Savas Deniz, Ruhstaller Thomas, Fehr Peter Martin, Knauer Michael, Pioch Verena, Güth Uwe, Hess Thomas, Tausch Christoph, Hayoz Stefanie, Fehr Mathias Konrad, Ribi Karin, Hawle Hanne, Lupatsch Judith Eva, Matter-Walstra Klazien, Chiesa Federica, Dedes Konstantin Johannes, Berclaz Gilles, Lelièvre Loic, Swiss Group for Clinical Cancer Research (SAKK)
Units
PubMed
Doi
Citation
Type
Journal
Publication Date
Issn Electronic
Pages
Brief description/objective
BACKGROUND
Several studies and a meta-analysis showed that fibrin sealant patches reduced lymphatic drainage after various lymphadenectomy procedures. Our goal was to investigate the impact of these patches on drainage after axillary dissection for breast cancer.
METHODS
In a phase III superiority trial, we randomized patients undergoing breast-conserving surgery at 14 Swiss sites to receive versus not receive three large TachoSil patches in the dissected axilla. Axillary drains were inserted in all patients. Patients and investigators assessing outcomes were blinded to group assignment. The primary endpoint was total volume of drainage.
RESULTS
Between March 2015 and December 2016, 142 patients were randomized (72 with TachoSil and 70 without). Mean total volume of drainage in the control group was 703 ml [95% confidence interval (CI) 512-895 ml]. Application of TachoSil did not significantly reduce the total volume of axillary drainage [mean difference (MD) -110 ml, 95% CI -316 to 94, p = 0.30]. A total of eight secondary endpoints related to drainage, morbidity, and quality of life were not improved by use of TachoSil. The mean total cost per patient did not differ significantly between the groups [34,253 Swiss Francs (95% CI 32,625-35,880) with TachoSil and 33,365 Swiss Francs (95% CI 31,771-34,961) without, p = 0.584]. In the TachoSil group, length of stay was longer (MD 1 day, 95% CI 0.3-1.7, p = 0.009), and improvement of pain was faster, although the latter difference was not significant [2 days (95% CI 1-4) vs. 5.5 days (95% CI 2-11); p = 0.2].
CONCLUSIONS
TachoSil reduced drainage after axillary dissection for breast cancer neither significantly nor relevantly.