Publication
Is the bare spot a consistent landmark for shoulder arthroscopy? A study of 20 embalmed glenoids with 3-dimensional computed tomographic reconstruction
Journal Paper/Review - Apr 1, 2006
Kralinger Franz, Aigner Felix, Longato Stefano, Rieger Michael, Wambacher Markus
Units
PubMed
Doi
Citation
Type
Journal
Publication Date
Issn Electronic
Pages
Brief description/objective
PURPOSE
Our aim was to test a published methodology for arthroscopically quantifying glenoid bone loss for its dependability in a cadaver-based anatomic study with 3-dimensional (3-D) computed tomographic (CT) reconstructions of 20 embalmed glenoids.
METHODS
Manual macroscopic measurements were made in a standardized fashion. In addition, we marked the center of the visible bare spot in 20 embalmed glenoids with a titanium pin. The shoulder joints were carefully selected for intact rotator cuff, missing capsule-labral deficiency, and absence of severe cartilage degeneration. 3-D reconstructed CT scans were evaluated for consistency of the bare spot.
RESULTS
The mean distance from the bare spot to the anterior margin measured manually was 10.9 mm (CT-based, 13.9 mm), to the posterior margin 13.7 mm (CT-based, 16.4 mm), and to the inferior margin 9.7 mm (CT-based, 15.1 mm). Distances were significantly different.
CONCLUSIONS
The bare spot did not prove its consistency in 20 carefully selected specimens. Therefore, we conclude that this methodology is not a reliable way to intraoperatively determine bony glenoid deficiency.
CLINICAL RELEVANCE
We recommend preoperative bilateral CT scans for evaluation of bony glenoid deficiency for exact quantification of the bone loss.