Publication
Correction of complex three-dimensional deformities at the proximal femur using indirect reduction with angle blade plate and patient-specific instruments: a technical note
Journal Paper/Review - Jul 3, 2021
Jud Lukas, Vlachopoulos Lazaros, Grob Karl
Units
PubMed
Doi
Citation
Type
Journal
Publication Date
Issn Electronic
Pages
Brief description/objective
BACKGROUND
Corrective osteotomies for complex proximal femoral deformities can be challenging; wherefore, subsidies in preoperative planning and during surgical procedures are considered helpful. Three-dimensional (3D) planning and patient-specific instruments (PSI) are already established in different orthopedic procedures. This study gives an overview on this technique at the proximal femur and proposes a new indirect reduction technique using an angle blade plate.
METHODS
Using computed tomography (CT) data, 3D models are generated serving for the preoperative 3D planning. Different guides are used for registration of the planning to the intraoperative situation and to perform the desired osteotomies with the following reduction task. A new valuable tool to perform the correction is the use of a combined osteotomy and implant-positioning guide, with indirect deformity reduction over an angle blade plate.
RESULTS
An overview of the advantages of 3D planning and the use of PSI in complex corrective osteotomies at the proximal femur is provided. Furthermore, a new technique with indirect deformity reduction over an angle blade plate is introduced.
CONCLUSION
Using 3D planning and PSI for complex corrective osteotomies at the proximal femur can be a useful tool in understanding the individual deformity and performing the aimed deformity reduction. The indirect reduction over the implant is a simple and valuable tool in achieving the desired correction, and concurrently, surgical exposure can be limited to a subvastus approach.